Experimental Physiology
	

Celebrating 100 years
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Quarterly Journal of Experimental Physiology 70.2 pp 177-187
© The Physiological Society 1985
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Taylor, D. E. M.
Right arrow Articles by Tukmachi, E. S. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Taylor, D. E. M.
Right arrow Articles by Tukmachi, E. S. A.

CONTRIBUTION OF INTERNAL AND EXTERNAL CAROTID BEDS TO COMMON CAROTID ARTERY INPUT IMPEDANCE IN THE DOG

David E. M. Taylor 1 and Emad S. A. Tukmachi 1

1 Department of Applied Physiology and Surgical Sciences, Royal College of Surgeons of England, Lincoln's Inn Fields, London WC2A 3PN

The input impedance of the canine common carotid artery has been obtained using high fidelity pressure and flow recordings at the level of the superior thyroid artery. From the impedance spectra initially, and following internal and external carotid artery occlusion, separate estimations of internal carotid, external carotid and external/internal collateral bed impedances were derived by the use of network theory. Studies were carried out on six dogs. The common carotid input resistance was 10·98±1·42 (S.E.M.) x 106 kN.m-5.s, while those for the internal, external and collateral beds were 48·80±7·12, 14·94±2·37 and 171·42±46·83 x 106 kN.m-5.s respectively. The impedance spectrum of the common carotid, external carotid and collateral beds were of a high impedance type with major reflexions, while that for the internal carotid bed was of low impedance type with much less reflexion. On standardization of impedance for tissue mass the resistance levels became 17·44±2·91 x 106 kN.m-5.s. 100 g-1 for internal and 85·41±4·75 x 106 kN.m-5.s. 100 g-1 for external carotid beds. Thus, common carotid input impedance differences between dog and man are due to differences in relative mass of tissue perfused by internal and external carotid arteries, rather than to different peripheral-bed characteristrics in the two species.

Submitted on July 5, 1984




This article has been cited by other articles:


Home page
Br. J. Ophthalmol.Home page
A. J Morgan and S. L Hosking
Non-invasive vascular impedance measures demonstrate ocular vasoconstriction during isometric exercise
Br. J. Ophthalmol., March 1, 2007; 91(3): 385 - 390.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the The Physiological Society.