Experimental Physiology
	

Celebrating 100 years
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Experimental Physiology 77.1 pp 109-117
© The Physiological Society 1992
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Szereda-Przestaszewska, M
Right arrow Articles by Barani, H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Szereda-Przestaszewska, M
Right arrow Articles by Barani, H
Experimental Physiology, Vol 77, Issue 1, 109-117
Copyright © 1992 by The Physiological Society


Article

Characteristics of augmented breaths provoked by almitrine bismesylate in cats

M Szereda-Przestaszewska, J Jakus, A Stransky, and H Barani

The contribution of almitrine bismesylate to the occurrence and pattern of augmented breaths was studied in fifteen spontaneously breathing, anaesthetized cats. Breathing was via a tracheostomy, while the laryngeal resistance to airflow was measured with the larynx isolated in situ. Almitrine bismesylate at a dose of 0.5 mg kg-1 of body weight was injected intravenously in the intact animals and following bilateral vagotomy which spared the right recurrent laryngeal nerve. Almitrine injected intravenously elicited augmented breaths within the first 45 s in thirteen cats and within 1 min in the remaining two cats. During augmented breaths inspiratory and expiratory airflows rose, the mean increases being 385.2 and 159.6% respectively above the controls (P less than 0.01). The inspiratory laryngeal resistance declined to 77.7% of the control (P less than 0.01) and expiratory laryngeal resistance increased by 95.4% above the control level (P less than 0.01). The inspiratory and expiratory times were prolonged by 56 and 58% compared with baseline breathing. Following the augmented breaths the respiratory airflows exceeded baseline values, the respiratory timing was slightly reduced, and the inspiratory laryngeal resistance was significantly lowered below the control level (P less than 0.01). The expiratory laryngeal resistance showed the same trend without statistical significance. Bilateral vagotomy abolished the occurrence of augmented breaths following almitrine injection.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the The Physiological Society.