|
|
||||||||
Article |
We have demonstrated that the fluorescent microsphere technique can be used in small mammals for accurate determination of regional blood flows. In particular we have shown that 100% recovery of trapped microspheres is possible, that tissue digestion can be completed in a shorter time than previously reported, and the error-prone filtration method can be replaced with one of sedimentation. The method gave very good agreement among different fluorescent labels (r2 > 0.99) and low variability among tissues (mean coefficient of variation = 0.06). Simultaneous injection of radiolabelled and fluorescent microspheres established comparability between these methods (r2 = 0.96) for blood flows measured at rest, during vasodilator-induced hypotension, and in muscle hyperaemia during indirect electrical stimulation. Fluorescent microspheres can therefore replace radioactive microspheres for the determination of blood flow with advantages in both safety and cost, without loss of sensitivity.
This article has been cited by other articles:
![]() |
M. J. Raher, H. Thibault, K. K. Poh, R. Liu, E. F. Halpern, G. Derumeaux, F. Ichinose, W. M. Zapol, K. D. Bloch, M. H. Picard, et al. In Vivo Characterization of Murine Myocardial Perfusion With Myocardial Contrast Echocardiography: Validation and Application in Nitric Oxide Synthase 3 Deficient Mice Circulation, September 11, 2007; 116(11): 1250 - 1257. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. Nork, C. B. Y. Kim, D. Shanmuganayagam, M. S. Van Lysel, J. N. Ver Hoeve, and J. D. Folts Measurement of regional choroidal blood flow in rabbits and monkeys using fluorescent microspheres. Arch Ophthalmol, June 1, 2006; 124(6): 860 - 868. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Sabharwal, E. J. Johns, and S. Egginton The influence of acute hypothermia on renal function of anaesthetized euthermic and acclimatized rats Exp Physiol, July 1, 2004; 89(4): 455 - 463. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. L. Duvall, W. Robert Taylor, D. Weiss, and R. E. Guldberg Quantitative microcomputed tomography analysis of collateral vessel development after ischemic injury Am J Physiol Heart Circ Physiol, July 1, 2004; 287(1): H302 - H310. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Boudina, M. N. Laclau, L. Tariosse, D. Daret, G. Gouverneur, S. Bonoron-Adele, V. A. Saks, and P. Dos Santos Alteration of mitochondrial function in a model of chronic ischemia in vivo in rat heart Am J Physiol Heart Circ Physiol, March 1, 2002; 282(3): H821 - H831. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |